Engineers' questions — Chema Foam

PROJECT SERVICES

Engineers' Questions

Share your engineering questions about project requirements, material systems and site conditions with our technical team.

When Your Project Needs A Clearer Path.

Share your engineering questions about project requirements, material systems and site conditions with our technical team.

Explore the engineering behind thermal insulation and waterproofing. Connect a question with a physical relationship, a worked example and an application decision, then use verified product data for project design.

  • Thermal engineering
  • Water & drainage
  • Integrated assemblies

What This Service Covers

Thermal Engineering

Understand thickness, conductivity, thermal resistance, U-value and steady-state heat transfer.

Water & Drainage

Explore hydrostatic pressure, roof falls, water exposure and system selection.

Integrated Assemblies

Review compressive loads, moisture sensitivity and the coordination of insulation, waterproofing and protection.

Engineering Insights

A question. A relationship. A practical decision. Explore thermal insulation and waterproofing with worked examples and interactive graphs.

Learning examples, not product ratings or a final design. Use the selected grade’s TDS and test reports. The project designer confirms loads, local requirements, moisture risks and the complete assembly.

Thermal insulation

How Does Insulation Thickness Affect Thermal Resistance?

For a homogeneous layer at constant conductivity, thermal resistance increases linearly with thickness. Use thickness in metres in the equation.

R = d / λ

R: m²·K/W · d: m · λ: W/(m·K)

Worked example

At assumed λ = 0.035 W/(m·K), 50 mm gives R = 1.43; 100 mm gives 2.86; 200 mm gives 5.71 m²·K/W.

Practical application

Select thickness against the complete assembly’s target U-value, available height and thermal bridges; layer R alone is not the roof U-value.

R (m²·K/W) / d (mm)
How does insulation thickness affect thermal resistance?Assumed conductivity λ (W/m·K): 0.035. 25: 0.71; 50: 1.43; 75: 2.14; 100: 2.86; 125: 3.57; 150: 4.29; 200: 5.71. View calculated values02.24.56.79R (m²·K/W)d (mm)25: 0.712550: 1.435075: 2.1475100: 2.86100125: 3.57125150: 4.29150200: 5.71200
View calculated values
d (mm)R (m²·K/W)
250.71
501.43
752.14
1002.86
1253.57
1504.29
2005.71

How Much Conductive Heat Flow Can Insulation Reduce?

Add the layer resistances and inside/outside surface resistances for a simple one-dimensional steady-state assembly, then calculate U and heat flow.

U = 1 / Rₜ ; Q = U × A × ΔT ; reduction = (Q₁ − Q₂) / Q₁ × 100%

Rₜ: total m²·K/W · U: W/(m²·K) · A: m² · ΔT: K · Q: W

Worked example

Assume R₀ = 0.50 m²·K/W including surface resistances, A = 100 m² and ΔT = 20 K. Before insulation Q = 4000 W. Adding 100 mm at λ = 0.035 gives U = 0.298 and Q ≈ 596 W: 85.1% less conduction under these assumptions.

Practical application

Use this comparison for the element under fixed conditions. It does not predict annual electricity savings or include solar gains, air leakage or HVAC efficiency.

Q (W) / d (mm)
How much conductive heat flow can insulation reduce?Assumed conductivity λ (W/m·K): 0.035. 0: 4,000; 25: 1,647.06; 50: 1,037.04; 75: 756.76; 100: 595.74; 150: 417.91; 200: 321.84. View calculated values01,1202,2403,3604,480Q (W)d (mm)0: 4,000025: 1,647.062550: 1,037.045075: 756.7675100: 595.74100150: 417.91150200: 321.84200
View calculated values
d (mm)Q (W)
04,000
251,647.06
501,037.04
75756.76
100595.74
150417.91
200321.84

Waterproofing

How Does Water Depth Affect Waterproofing Pressure?

For static fresh water, gauge pressure grows linearly with vertical depth below the free surface. This is pressure above the surface reference pressure.

p = ρ × g × h

ρ = 1000 kg/m³ · g = 9.81 m/s² · h: m · p: Pa (divide by 1000 for kPa)

Worked example

At depths of 1, 3 and 5 m, gauge pressures are 9.81, 29.43 and 49.05 kPa respectively.

Practical application

Review design water level, pressure direction, joints and substrate. A membrane’s suitability must be verified from system tests; this calculation does not establish pressure resistance.

Technical referencesNASA — Fluid Pressure
p (kPa) / h (m)
How does water depth affect waterproofing pressure?Assumed water density ρ (kg/m³): 1,000. 0: 0; 1: 9.81; 2: 19.62; 3: 29.43; 4: 39.24; 5: 49.05. View calculated values014.128.342.456.6p (kPa)h (m)0: 001: 9.8112: 19.6223: 29.4334: 39.2445: 49.055
View calculated values
h (m)p (kPa)
00
19.81
219.62
329.43
439.24
549.05

Why Do Roof Falls And Drainage Matter?

Falls direct water towards outlets and limit ponding. Geometry alone cannot size drains: rainfall intensity, catchment, outlet capacity and overflow provision also matter.

S = (Δh / L) × 100%

Δh and L must use the same length unit · S: %

Worked example

An illustrative 1.5% fall over a 10 m horizontal run requires 0.15 m = 150 mm level difference. This is a geometry example, not a universal minimum slope.

Practical application

Coordinate falls, thresholds, outlets and structural deflection. Confirm the project’s minimum finished falls and drainage design with its designer.

Technical referencesNASA — Fluid Pressure
Δh (mm) / L (m)
Why do roof falls and drainage matter?Illustrative slope S (%): 1.5. 0: 0; 2: 30; 4: 60; 6: 90; 8: 120; 10: 150. View calculated values084168252336Δh (mm)L (m)0: 002: 3024: 6046: 9068: 120810: 15010
View calculated values
L (m)Δh (mm)
00
230
460
690
8120
10150

How Is The Right Waterproofing System Selected?

Start with the source of water and whether treatment is on the positive side facing water or the negative side. Check substrate, cracks, joints, UV/chemical exposure and protection needs.

p = ρgh → exposure + substrate + movement + compatibility

Selection framework; pressure alone is insufficient to specify a system.

Worked example

A buried wall with a 3 m design water head sees about 29.43 kPa gauge pressure. Unlike an exposed roof, it also needs assessment of ground conditions, joints and protection during backfilling.

Practical application

Request documented pressure direction, crack-bridging performance and compatible detailing. Confirm suitability for potable water or chemical exposure explicitly where required.

Technical referencesNASA — Fluid Pressure
Practical application
  1. Identify water source and pressure direction
  2. Assess substrate, cracks and movement joints
  3. Check UV, chemical and service exposure
  4. Confirm system test data and compatible protection

Integrated systems

How Do Density And Compressive Performance Affect Selection?

Density alone does not define allowable loading. Check stress, load distribution and the grade’s tested short-term behaviour and long-term creep data.

σ = F / A

F: kN · A: m² · σ: kPa (1 kN/m² = 1 kPa)

Worked example

A uniformly distributed 20 kN load over 2 m² gives 10 kPa average stress. The same load over 0.1 m² gives 200 kPa before any load-spreading effect.

Practical application

Check point loads, finishes and sustained service loads with the designer. A stress reported at 10% deformation is a test characteristic, not an automatically allowable design stress.

σ (kPa) / A (m²)
How do density and compressive performance affect selection?Applied force F (kN): 20. 0.1: 200; 0.25: 80; 0.5: 40; 1: 20; 1.5: 13.33; 2: 10. View calculated values02805608401,120σ (kPa)A (m²)0.1: 2000.10.25: 800.250.5: 400.51: 2011.5: 13.331.52: 102
View calculated values
A (m²)σ (kPa)
0.1200
0.2580
0.540
120
1.513.33
210

How Do Thermal Insulation And Waterproofing Work Together?

Coordinate the entire assembly rather than placing independent materials together. The membrane can be above insulation in a warm roof or below suitable insulation in an inverted roof, with the required drainage, separation and protection.

Rₜ = Rsi + Σ(dᵢ / λᵢ) + Rse ; U = 1 / Rₜ

Basic 1D resistance sum; account separately for bridges, moisture and applicable inverted-roof corrections.

Worked example

Conceptual inverted-roof order, from inside out: structure / falls → waterproofing → suitable thermal insulation → separation and drainage → protection / ballast. Actual falls and drainage positions depend on the approved system.

Practical application

Resolve vapour control by climate and internal humidity analysis, plus wind uplift, fire requirements, loading, joints and drain levels. This conceptual order is not a construction detail.

Practical application
  1. Structure and designed falls
  2. Waterproofing with coordinated joints and outlets
  3. Thermal insulation suitable for the exposure and loads
  4. Separation, drainage and protection as specified

What Happens When Insulation Is Exposed To Moisture?

Moisture can change effective conductivity and thermal performance. The response depends on the product, test conditions and exposure history; there is no universal moisture-to-conductivity curve.

R = d / λeffective

Sensitivity to assumed λ, not a prediction from moisture content.

Worked example

At a fixed 100 mm thickness, assumed λ increasing from 0.035 to 0.045 W/(m·K) reduces R from 2.86 to 2.22 m²·K/W (22.2%). These values are hypothetical, not wet-product test results.

Practical application

Use product-specific water-absorption and ageing data, with the specified test method. ASTM C272 concerns sandwich-core absorption; cite it only when it is the method in the relevant report.

R (m²·K/W) / λ (W/m·K)
What happens when insulation is exposed to moisture?Fixed insulation thickness d (mm): 100. 0.03: 3.33; 0.035: 2.86; 0.04: 2.5; 0.045: 2.22; 0.05: 2; 0.055: 1.82; 0.06: 1.67. View calculated values01.93.75.67.5R (m²·K/W)λ (W/m·K)0.03: 3.330.030.035: 2.860.0350.04: 2.50.040.045: 2.220.0450.05: 20.050.055: 1.820.0550.06: 1.670.06
View calculated values
λ (W/m·K)R (m²·K/W)
0.033.33
0.0352.86
0.042.5
0.0452.22
0.052
0.0551.82
0.061.67

From Your Brief To The Next Decision

  1. State The Problem

    Identify the element, boundary conditions and the design question.

  2. Check The Inputs

    Use consistent SI units and distinguish assumed values from tested product data.

  3. Explore The Relationship

    Adjust the example graphs and compare the calculated results.

  4. Apply To Your Project

    Share drawings and verified values with the technical team; the project designer confirms the final assembly.

What To Prepare For Your Enquiry

  • Your engineering question and project element
  • Drawings, layer thicknesses and material data sheets
  • Temperatures, loads, water depth or drainage constraints
  • Required performance and applicable project specification
Discuss your project

Related Materials

Chema Ultra Light

Chema Ultra Light is a ready-to-use, single-component flexible acrylic coating designed for thermal insulation and waterproofing.

View product

CHEMA ADHESIVE 103

CHEMA ADHESIVE 103 is a single-component, cement-based strengthened adhesive mortar made from cement, sand, and selected admixtures.

View product

Chema White

Chema White is expanded polystyrene (EPS) foam used for multiple applications such as expansion joint and void filling and wall thermal insulation.

View product

Send Your Engineering Question

Choose a topic and share your question, dimensions, layer build-up and known engineering inputs. State which values are assumed.

Preparing your enquiry form…

Engineers' Questions

Share your engineering questions about project requirements, material systems and site conditions with our technical team.

Frequently asked questions

Are the example values product specifications?

No. They are explicitly stated assumptions for learning. Use the selected product’s current TDS and test reports for conductivity, compressive strength and water absorption.

Does reduced heat transfer equal electricity savings?

No. These examples describe conduction through an element at fixed conditions. Building energy use also depends on weather, solar gains, air leakage, occupancy and HVAC efficiency.

Which service should I contact first?

Choose design for system development, execution for site work, or technical support and consulting for a focused review.

What should I include in a service enquiry?

Include the location, project stage, expected deliverables and helpful drawings or photos.

Can I ask for a review of an existing system?

Describe the installed layers and substrate and share photos and previous work records if available.

All questions