Thermal Engineering
Understand thickness, conductivity, thermal resistance, U-value and steady-state heat transfer.

PROJECT SERVICES
Share your engineering questions about project requirements, material systems and site conditions with our technical team.

Share your engineering questions about project requirements, material systems and site conditions with our technical team.
Explore the engineering behind thermal insulation and waterproofing. Connect a question with a physical relationship, a worked example and an application decision, then use verified product data for project design.
Understand thickness, conductivity, thermal resistance, U-value and steady-state heat transfer.
Explore hydrostatic pressure, roof falls, water exposure and system selection.
Review compressive loads, moisture sensitivity and the coordination of insulation, waterproofing and protection.
A question. A relationship. A practical decision. Explore thermal insulation and waterproofing with worked examples and interactive graphs.
Learning examples, not product ratings or a final design. Use the selected grade’s TDS and test reports. The project designer confirms loads, local requirements, moisture risks and the complete assembly.
For a homogeneous layer at constant conductivity, thermal resistance increases linearly with thickness. Use thickness in metres in the equation.
R = d / λ
R: m²·K/W · d: m · λ: W/(m·K)
At assumed λ = 0.035 W/(m·K), 50 mm gives R = 1.43; 100 mm gives 2.86; 200 mm gives 5.71 m²·K/W.
Select thickness against the complete assembly’s target U-value, available height and thermal bridges; layer R alone is not the roof U-value.
| d (mm) | R (m²·K/W) |
|---|---|
| 25 | 0.71 |
| 50 | 1.43 |
| 75 | 2.14 |
| 100 | 2.86 |
| 125 | 3.57 |
| 150 | 4.29 |
| 200 | 5.71 |
Add the layer resistances and inside/outside surface resistances for a simple one-dimensional steady-state assembly, then calculate U and heat flow.
U = 1 / Rₜ ; Q = U × A × ΔT ; reduction = (Q₁ − Q₂) / Q₁ × 100%
Rₜ: total m²·K/W · U: W/(m²·K) · A: m² · ΔT: K · Q: W
Assume R₀ = 0.50 m²·K/W including surface resistances, A = 100 m² and ΔT = 20 K. Before insulation Q = 4000 W. Adding 100 mm at λ = 0.035 gives U = 0.298 and Q ≈ 596 W: 85.1% less conduction under these assumptions.
Use this comparison for the element under fixed conditions. It does not predict annual electricity savings or include solar gains, air leakage or HVAC efficiency.
| d (mm) | Q (W) |
|---|---|
| 0 | 4,000 |
| 25 | 1,647.06 |
| 50 | 1,037.04 |
| 75 | 756.76 |
| 100 | 595.74 |
| 150 | 417.91 |
| 200 | 321.84 |
For static fresh water, gauge pressure grows linearly with vertical depth below the free surface. This is pressure above the surface reference pressure.
p = ρ × g × h
ρ = 1000 kg/m³ · g = 9.81 m/s² · h: m · p: Pa (divide by 1000 for kPa)
At depths of 1, 3 and 5 m, gauge pressures are 9.81, 29.43 and 49.05 kPa respectively.
Review design water level, pressure direction, joints and substrate. A membrane’s suitability must be verified from system tests; this calculation does not establish pressure resistance.
| h (m) | p (kPa) |
|---|---|
| 0 | 0 |
| 1 | 9.81 |
| 2 | 19.62 |
| 3 | 29.43 |
| 4 | 39.24 |
| 5 | 49.05 |
Falls direct water towards outlets and limit ponding. Geometry alone cannot size drains: rainfall intensity, catchment, outlet capacity and overflow provision also matter.
S = (Δh / L) × 100%
Δh and L must use the same length unit · S: %
An illustrative 1.5% fall over a 10 m horizontal run requires 0.15 m = 150 mm level difference. This is a geometry example, not a universal minimum slope.
Coordinate falls, thresholds, outlets and structural deflection. Confirm the project’s minimum finished falls and drainage design with its designer.
| L (m) | Δh (mm) |
|---|---|
| 0 | 0 |
| 2 | 30 |
| 4 | 60 |
| 6 | 90 |
| 8 | 120 |
| 10 | 150 |
Start with the source of water and whether treatment is on the positive side facing water or the negative side. Check substrate, cracks, joints, UV/chemical exposure and protection needs.
p = ρgh → exposure + substrate + movement + compatibility
Selection framework; pressure alone is insufficient to specify a system.
A buried wall with a 3 m design water head sees about 29.43 kPa gauge pressure. Unlike an exposed roof, it also needs assessment of ground conditions, joints and protection during backfilling.
Request documented pressure direction, crack-bridging performance and compatible detailing. Confirm suitability for potable water or chemical exposure explicitly where required.
Density alone does not define allowable loading. Check stress, load distribution and the grade’s tested short-term behaviour and long-term creep data.
σ = F / A
F: kN · A: m² · σ: kPa (1 kN/m² = 1 kPa)
A uniformly distributed 20 kN load over 2 m² gives 10 kPa average stress. The same load over 0.1 m² gives 200 kPa before any load-spreading effect.
Check point loads, finishes and sustained service loads with the designer. A stress reported at 10% deformation is a test characteristic, not an automatically allowable design stress.
| A (m²) | σ (kPa) |
|---|---|
| 0.1 | 200 |
| 0.25 | 80 |
| 0.5 | 40 |
| 1 | 20 |
| 1.5 | 13.33 |
| 2 | 10 |
Coordinate the entire assembly rather than placing independent materials together. The membrane can be above insulation in a warm roof or below suitable insulation in an inverted roof, with the required drainage, separation and protection.
Rₜ = Rsi + Σ(dᵢ / λᵢ) + Rse ; U = 1 / Rₜ
Basic 1D resistance sum; account separately for bridges, moisture and applicable inverted-roof corrections.
Conceptual inverted-roof order, from inside out: structure / falls → waterproofing → suitable thermal insulation → separation and drainage → protection / ballast. Actual falls and drainage positions depend on the approved system.
Resolve vapour control by climate and internal humidity analysis, plus wind uplift, fire requirements, loading, joints and drain levels. This conceptual order is not a construction detail.
Moisture can change effective conductivity and thermal performance. The response depends on the product, test conditions and exposure history; there is no universal moisture-to-conductivity curve.
R = d / λeffective
Sensitivity to assumed λ, not a prediction from moisture content.
At a fixed 100 mm thickness, assumed λ increasing from 0.035 to 0.045 W/(m·K) reduces R from 2.86 to 2.22 m²·K/W (22.2%). These values are hypothetical, not wet-product test results.
Use product-specific water-absorption and ageing data, with the specified test method. ASTM C272 concerns sandwich-core absorption; cite it only when it is the method in the relevant report.
| λ (W/m·K) | R (m²·K/W) |
|---|---|
| 0.03 | 3.33 |
| 0.035 | 2.86 |
| 0.04 | 2.5 |
| 0.045 | 2.22 |
| 0.05 | 2 |
| 0.055 | 1.82 |
| 0.06 | 1.67 |
Identify the element, boundary conditions and the design question.
Use consistent SI units and distinguish assumed values from tested product data.
Adjust the example graphs and compare the calculated results.
Share drawings and verified values with the technical team; the project designer confirms the final assembly.
CHEMA STANDARD is extruded polystyrene (XPS) foam insulation designed for building roofs and walls.
View productChema Ultra Light is a ready-to-use, single-component flexible acrylic coating designed for thermal insulation and waterproofing.
View productCHEMA ADHESIVE 103 is a single-component, cement-based strengthened adhesive mortar made from cement, sand, and selected admixtures.
View productChema White is expanded polystyrene (EPS) foam used for multiple applications such as expansion joint and void filling and wall thermal insulation.
View productChoose a topic and share your question, dimensions, layer build-up and known engineering inputs. State which values are assumed.
Preparing your enquiry form…
Share your engineering questions about project requirements, material systems and site conditions with our technical team.
No. They are explicitly stated assumptions for learning. Use the selected product’s current TDS and test reports for conductivity, compressive strength and water absorption.
No. These examples describe conduction through an element at fixed conditions. Building energy use also depends on weather, solar gains, air leakage, occupancy and HVAC efficiency.
Choose design for system development, execution for site work, or technical support and consulting for a focused review.
Include the location, project stage, expected deliverables and helpful drawings or photos.
Describe the installed layers and substrate and share photos and previous work records if available.