ASTM C578 Classification
Classified according to ASTM C578.
Thermal insulation
Expanded Polystyrene (EPS) Thermal Insulation Foam
Chema White is expanded polystyrene (EPS) foam used for multiple applications such as expansion joint and void filling and wall thermal insulation. Classified according to ASTM C578, it is available in seven densities from 10 to 35 kg/m³ and offers excellent thermal insulation, dimensional stability, and easy handling and installation.
Chema White is expanded polystyrene (EPS) foam for building and industrial uses: roof, wall and floor insulation; lightweight expansion-joint filling in concrete; refrigerated trucks, containers and mobile cooling systems; packaging and protection; and floor leveling and lightweight fill.
Classified according to ASTM C578, it is available in densities of 10, 12, 15, 20, 25, 30 and 35 kg/m³. Thermal conductivity ranges from ≤0.041 W/m·K at 10 kg/m³ to ≤0.033 W/m·K at 35 kg/m³ (ASTM C518). Compression at 10% deformation ranges from ≥35 to ≥240 kPa (ASTM D1621), and dimensional stability is ≤2% for every density (EN 1604).
Chema White saves up to 40% of electricity consumption, has a maximum service temperature of 74°C and low water absorption. Its fire performance is Class B with flame spread index ≤75 and smoke developed index ≤450 (ASTM E84). As density increases, strength increases and thermal conductivity decreases; select density to suit the application.
Key benefits
Classified according to ASTM C578.
Saves up to 40% of electricity consumption.
Conductivity from ≤0.041 to ≤0.033 W/m·K, with R-value 6.9–8.6 ft²·°F·h/BTU at 50 mm thickness, depending on density.
≤2% for every density under EN 1604.
10, 12, 15, 20, 25, 30 and 35 kg/m³, with compression at 10% deformation from ≥35 to ≥240 kPa.
≤1.8% to ≤0.50% by volume (ASTM C272), and ≤3% by volume by immersion (EN 12087).
Flame spread index ≤75 and smoke developed index ≤450 (ASTM E84); Class B. Passes the single flame test (EN ISO 11925-2) with a flame height <150 mm.
Lightweight boards that are easy to handle and install.
Lightweight expanded polystyrene (EPS) white foam boards for thermal insulation, expansion joints, internal level raising and floating pontoons, offering multiple densities and up to 40% energy savings.



| Property | Test standard | Value |
|---|---|---|
| Available densities | 10 / 12 / 15 / 20 / 25 / 30 / 35 kg/m³ | |
| Compressive strength at 10% deformation | ASTM D1621 | 10 kg/m³: ≥35 kPa; 12 kg/m³: ≥50 kPa; 15 kg/m³: ≥80 kPa; 20 kg/m³: ≥110 kPa; 25 kg/m³: ≥165 kPa; 30 kg/m³: ≥210 kPa; 35 kg/m³: ≥240 kPa |
| Flexural strength | ASTM C203 | 10 kg/m³: ≥100 kPa; 12 kg/m³: ≥130 kPa; 15 kg/m³: ≥180 kPa; 20 kg/m³: ≥280 kPa; 25 kg/m³: ≥340 kPa; 30 kg/m³: ≥430 kPa; 35 kg/m³: ≥520 kPa |
| Tensile strength | EN 1607 | 10 kg/m³: ≥60 kPa; 12 kg/m³: ≥80 kPa; 15 kg/m³: ≥100 kPa; 20 kg/m³: ≥120 kPa; 25 kg/m³: ≥150 kPa; 30 kg/m³: ≥180 kPa; 35 kg/m³: ≥200 kPa |
| Dimensional stability | EN 1604 | 10 kg/m³: ≤2 %; 12 kg/m³: ≤2 %; 15 kg/m³: ≤2 %; 20 kg/m³: ≤2 %; 25 kg/m³: ≤2 %; 30 kg/m³: ≤2 %; 35 kg/m³: ≤2 % |
| Thermal conductivity (λ) | ASTM C518 | 10 kg/m³: ≤0.041 W/m·K; 12 kg/m³: ≤0.040 W/m·K; 15 kg/m³: ≤0.039 W/m·K; 20 kg/m³: ≤0.037 W/m·K; 25 kg/m³: ≤0.035 W/m·K; 30 kg/m³: ≤0.034 W/m·K; 35 kg/m³: ≤0.033 W/m·K |
| Thermal resistance at 50 mm | EN 12667 | 10 kg/m³: 1.22 m²·K/W; 12 kg/m³: 1.25 m²·K/W; 15 kg/m³: 1.28 m²·K/W; 20 kg/m³: 1.35 m²·K/W; 25 kg/m³: 1.42 m²·K/W; 30 kg/m³: 1.47 m²·K/W; 35 kg/m³: 1.52 m²·K/W |
| R-value at 50 mm | ASTM C518 | 10 kg/m³: 6.9 ft²·°F·h/BTU; 12 kg/m³: 7.1 ft²·°F·h/BTU; 15 kg/m³: 7.3 ft²·°F·h/BTU; 20 kg/m³: 7.7 ft²·°F·h/BTU; 25 kg/m³: 8.1 ft²·°F·h/BTU; 30 kg/m³: 8.3 ft²·°F·h/BTU; 35 kg/m³: 8.6 ft²·°F·h/BTU |
| Specific heat capacity | EN 12524 | 10 kg/m³: 1450 J/kg·K; 12 kg/m³: 1450 J/kg·K; 15 kg/m³: 1450 J/kg·K; 20 kg/m³: 1450 J/kg·K; 25 kg/m³: 1450 J/kg·K; 30 kg/m³: 1450 J/kg·K; 35 kg/m³: 1450 J/kg·K |
| Maximum service temperature | 10 kg/m³: 74 °C; 12 kg/m³: 74 °C; 15 kg/m³: 74 °C; 20 kg/m³: 74 °C; 25 kg/m³: 74 °C; 30 kg/m³: 74 °C; 35 kg/m³: 74 °C | |
| Water absorption | ASTM C272 | 10 kg/m³: ≤1.8 % vol; 12 kg/m³: ≤1.5 % vol; 15 kg/m³: ≤1.25 % vol; 20 kg/m³: ≤0.95 % vol; 25 kg/m³: ≤0.70 % vol; 30 kg/m³: ≤0.60 % vol; 35 kg/m³: ≤0.50 % vol |
| Water vapour diffusion resistance | EN 12086 | 10 kg/m³: 20–40 μ; 12 kg/m³: 30–70 μ; 15 kg/m³: 30–70 μ; 20 kg/m³: 40–80 μ; 25 kg/m³: 40–80 μ; 30 kg/m³: 40–100 μ; 35 kg/m³: 40–120 μ |
| Water absorption by immersion | EN 12087 | 10 kg/m³: ≤3 % vol; 12 kg/m³: ≤3 % vol; 15 kg/m³: ≤3 % vol; 20 kg/m³: ≤3 % vol; 25 kg/m³: ≤3 % vol; 30 kg/m³: ≤3 % vol; 35 kg/m³: ≤3 % vol |
| Flame spread index | ASTM E84 | ≤75 |
| Smoke developed index | ASTM E84 | ≤450 |
| Single flame test | EN ISO 11925-2 | Pass (<150 mm flame height) |
| Electricity saving | Saves up to 40% of electricity consumption. |
1 kPa ≈ 0.1 ton/m². Thermal resistance and R-value are stated at 50 mm thickness in their respective units. For other thicknesses: thermal resistance (m²·K/W) = thickness (m) ÷ thermal conductivity λ (W/m·K).
Thermal insulation reduces heat transfer through the building envelope and helps save up to 40% of electricity consumption.
Lightweight expansion-joint and void filler in concrete structures.
Insulation for refrigerated trucks, containers and mobile cooling systems.
Lightweight protective packaging for products and equipment.
Lightweight fill for leveling floors and filling voids.
Boards are breakable; handle with care.
Keep away from sparks and flame.
Avoid contact with strong oxidizing agents and aromatic solvents.
Avoid stacking boards on their edges.
Use only adhesives, coatings and sealants compatible with polystyrene.
Share your quantities and project details. Our team will help you select the right specification.
Thermal insulation
Preparing your enquiry form…
Our technical team can help with product selection and project quantities.
Expanded polystyrene (EPS) foam for expansion joint and void filling, wall thermal insulation and other listed applications, classified according to ASTM C578.
Roof, wall and floor insulation; lightweight expansion-joint filling in concrete; refrigerated trucks, containers and mobile cooling; packaging/protection; and floor leveling/lightweight fill.
10 / 12 / 15 / 20 / 25 / 30 / 35 kg/m³
10 kg/m³: ≤0.041 W/m·K; 12 kg/m³: ≤0.040 W/m·K; 15 kg/m³: ≤0.039 W/m·K; 20 kg/m³: ≤0.037 W/m·K; 25 kg/m³: ≤0.035 W/m·K; 30 kg/m³: ≤0.034 W/m·K; 35 kg/m³: ≤0.033 W/m·K
At 50 mm, R-value (ASTM C518) ranges from 6.9 to 8.6 ft²·°F·h/BTU across 10–35 kg/m³. Thermal resistance (EN 12667) ranges from 1.22 to 1.52 m²·K/W.