Thermal insulation

Chema White

Expanded Polystyrene (EPS) Thermal Insulation Foam

Chema White is expanded polystyrene (EPS) foam used for multiple applications such as expansion joint and void filling and wall thermal insulation. Classified according to ASTM C578, it is available in seven densities from 10 to 35 kg/m³ and offers excellent thermal insulation, dimensional stability, and easy handling and installation.

10–35 kg/m³
Seven available densities
≥35–≥240 kPa
Compression at 10% deformation · by density
74°C
Maximum service temperature
40%
Electricity saving · up to

Overview

Chema White is expanded polystyrene (EPS) foam for building and industrial uses: roof, wall and floor insulation; lightweight expansion-joint filling in concrete; refrigerated trucks, containers and mobile cooling systems; packaging and protection; and floor leveling and lightweight fill.

Classified according to ASTM C578, it is available in densities of 10, 12, 15, 20, 25, 30 and 35 kg/m³. Thermal conductivity ranges from ≤0.041 W/m·K at 10 kg/m³ to ≤0.033 W/m·K at 35 kg/m³ (ASTM C518). Compression at 10% deformation ranges from ≥35 to ≥240 kPa (ASTM D1621), and dimensional stability is ≤2% for every density (EN 1604).

Chema White saves up to 40% of electricity consumption, has a maximum service temperature of 74°C and low water absorption. Its fire performance is Class B with flame spread index ≤75 and smoke developed index ≤450 (ASTM E84). As density increases, strength increases and thermal conductivity decreases; select density to suit the application.

Key benefits

ASTM C578 Classification

Classified according to ASTM C578.

Energy Saving

Saves up to 40% of electricity consumption.

Excellent Thermal Insulation

Conductivity from ≤0.041 to ≤0.033 W/m·K, with R-value 6.9–8.6 ft²·°F·h/BTU at 50 mm thickness, depending on density.

Dimensional Stability

≤2% for every density under EN 1604.

Seven Density Grades

10, 12, 15, 20, 25, 30 and 35 kg/m³, with compression at 10% deformation from ≥35 to ≥240 kPa.

Low Water Absorption

≤1.8% to ≤0.50% by volume (ASTM C272), and ≤3% by volume by immersion (EN 12087).

Fire Performance

Flame spread index ≤75 and smoke developed index ≤450 (ASTM E84); Class B. Passes the single flame test (EN ISO 11925-2) with a flame height <150 mm.

Easy Handling And Installation

Lightweight boards that are easy to handle and install.

Product videos

Thermal insulation using White EPS Foam boards · Chema White

Lightweight expanded polystyrene (EPS) white foam boards for thermal insulation, expansion joints, internal level raising and floating pontoons, offering multiple densities and up to 40% energy savings.

White expanded polystyrene insulation on a masonry wall
White expanded polystyrene insulation on a masonry wall
White expanded polystyrene insulation on a masonry wall

Technical specifications

Material
Expanded polystyrene (EPS) foam
Classification
ASTM C578ASTM C578
Reaction to fire
Class BASTM E84
Technical specifications
PropertyTest standardValue
Available densities10 / 12 / 15 / 20 / 25 / 30 / 35 kg/m³
Compressive strength at 10% deformationASTM D162110 kg/m³: ≥35 kPa; 12 kg/m³: ≥50 kPa; 15 kg/m³: ≥80 kPa; 20 kg/m³: ≥110 kPa; 25 kg/m³: ≥165 kPa; 30 kg/m³: ≥210 kPa; 35 kg/m³: ≥240 kPa
Flexural strengthASTM C20310 kg/m³: ≥100 kPa; 12 kg/m³: ≥130 kPa; 15 kg/m³: ≥180 kPa; 20 kg/m³: ≥280 kPa; 25 kg/m³: ≥340 kPa; 30 kg/m³: ≥430 kPa; 35 kg/m³: ≥520 kPa
Tensile strengthEN 160710 kg/m³: ≥60 kPa; 12 kg/m³: ≥80 kPa; 15 kg/m³: ≥100 kPa; 20 kg/m³: ≥120 kPa; 25 kg/m³: ≥150 kPa; 30 kg/m³: ≥180 kPa; 35 kg/m³: ≥200 kPa
Dimensional stabilityEN 160410 kg/m³: ≤2 %; 12 kg/m³: ≤2 %; 15 kg/m³: ≤2 %; 20 kg/m³: ≤2 %; 25 kg/m³: ≤2 %; 30 kg/m³: ≤2 %; 35 kg/m³: ≤2 %
Thermal conductivity (λ)ASTM C51810 kg/m³: ≤0.041 W/m·K; 12 kg/m³: ≤0.040 W/m·K; 15 kg/m³: ≤0.039 W/m·K; 20 kg/m³: ≤0.037 W/m·K; 25 kg/m³: ≤0.035 W/m·K; 30 kg/m³: ≤0.034 W/m·K; 35 kg/m³: ≤0.033 W/m·K
Thermal resistance at 50 mmEN 1266710 kg/m³: 1.22 m²·K/W; 12 kg/m³: 1.25 m²·K/W; 15 kg/m³: 1.28 m²·K/W; 20 kg/m³: 1.35 m²·K/W; 25 kg/m³: 1.42 m²·K/W; 30 kg/m³: 1.47 m²·K/W; 35 kg/m³: 1.52 m²·K/W
R-value at 50 mmASTM C51810 kg/m³: 6.9 ft²·°F·h/BTU; 12 kg/m³: 7.1 ft²·°F·h/BTU; 15 kg/m³: 7.3 ft²·°F·h/BTU; 20 kg/m³: 7.7 ft²·°F·h/BTU; 25 kg/m³: 8.1 ft²·°F·h/BTU; 30 kg/m³: 8.3 ft²·°F·h/BTU; 35 kg/m³: 8.6 ft²·°F·h/BTU
Specific heat capacityEN 1252410 kg/m³: 1450 J/kg·K; 12 kg/m³: 1450 J/kg·K; 15 kg/m³: 1450 J/kg·K; 20 kg/m³: 1450 J/kg·K; 25 kg/m³: 1450 J/kg·K; 30 kg/m³: 1450 J/kg·K; 35 kg/m³: 1450 J/kg·K
Maximum service temperature10 kg/m³: 74 °C; 12 kg/m³: 74 °C; 15 kg/m³: 74 °C; 20 kg/m³: 74 °C; 25 kg/m³: 74 °C; 30 kg/m³: 74 °C; 35 kg/m³: 74 °C
Water absorptionASTM C27210 kg/m³: ≤1.8 % vol; 12 kg/m³: ≤1.5 % vol; 15 kg/m³: ≤1.25 % vol; 20 kg/m³: ≤0.95 % vol; 25 kg/m³: ≤0.70 % vol; 30 kg/m³: ≤0.60 % vol; 35 kg/m³: ≤0.50 % vol
Water vapour diffusion resistanceEN 1208610 kg/m³: 20–40 μ; 12 kg/m³: 30–70 μ; 15 kg/m³: 30–70 μ; 20 kg/m³: 40–80 μ; 25 kg/m³: 40–80 μ; 30 kg/m³: 40–100 μ; 35 kg/m³: 40–120 μ
Water absorption by immersionEN 1208710 kg/m³: ≤3 % vol; 12 kg/m³: ≤3 % vol; 15 kg/m³: ≤3 % vol; 20 kg/m³: ≤3 % vol; 25 kg/m³: ≤3 % vol; 30 kg/m³: ≤3 % vol; 35 kg/m³: ≤3 % vol
Flame spread indexASTM E84≤75
Smoke developed indexASTM E84≤450
Single flame testEN ISO 11925-2Pass (<150 mm flame height)
Electricity savingSaves up to 40% of electricity consumption.

1 kPa ≈ 0.1 ton/m². Thermal resistance and R-value are stated at 50 mm thickness in their respective units. For other thicknesses: thermal resistance (m²·K/W) = thickness (m) ÷ thermal conductivity λ (W/m·K).

Applications

Roofs, Walls And Floors

Thermal insulation reduces heat transfer through the building envelope and helps save up to 40% of electricity consumption.

Expansion Joints And Voids

Lightweight expansion-joint and void filler in concrete structures.

Refrigerated Transport And Cooling

Insulation for refrigerated trucks, containers and mobile cooling systems.

Packaging And Protection

Lightweight protective packaging for products and equipment.

Floor Leveling And Lightweight Fill

Lightweight fill for leveling floors and filling voids.

How to apply

  1. 01

    Handle With Care

    Boards are breakable; handle with care.

  2. 02

    Keep Away From Ignition Sources

    Keep away from sparks and flame.

  3. 03

    Avoid Incompatible Chemicals

    Avoid contact with strong oxidizing agents and aromatic solvents.

  4. 04

    Stack Carefully

    Avoid stacking boards on their edges.

  5. 05

    Use Compatible Materials

    Use only adhesives, coatings and sealants compatible with polystyrene.

Request a quotation

Share your quantities and project details. Our team will help you select the right specification.

Thermal insulation

Chema White

Material
Expanded polystyrene (EPS) foam
Classification
ASTM C578
Available densities
10 / 12 / 15 / 20 / 25 / 30 / 35 kg/m³
Compressive strength at 10% deformation
10 kg/m³: ≥35 kPa; 12 kg/m³: ≥50 kPa; 15 kg/m³: ≥80 kPa; 20 kg/m³: ≥110 kPa; 25 kg/m³: ≥165 kPa; 30 kg/m³: ≥210 kPa; 35 kg/m³: ≥240 kPa

Preparing your enquiry form…

Need help choosing?

Our technical team can help with product selection and project quantities.

Calculate with Chemasure

Frequently asked questions

What is Chema White?

Expanded polystyrene (EPS) foam for expansion joint and void filling, wall thermal insulation and other listed applications, classified according to ASTM C578.

What is Chema White used for?

Roof, wall and floor insulation; lightweight expansion-joint filling in concrete; refrigerated trucks, containers and mobile cooling; packaging/protection; and floor leveling/lightweight fill.

Which densities are available?

10 / 12 / 15 / 20 / 25 / 30 / 35 kg/m³

What is the thermal conductivity?

10 kg/m³: ≤0.041 W/m·K; 12 kg/m³: ≤0.040 W/m·K; 15 kg/m³: ≤0.039 W/m·K; 20 kg/m³: ≤0.037 W/m·K; 25 kg/m³: ≤0.035 W/m·K; 30 kg/m³: ≤0.034 W/m·K; 35 kg/m³: ≤0.033 W/m·K

What is the R-value?

At 50 mm, R-value (ASTM C518) ranges from 6.9 to 8.6 ft²·°F·h/BTU across 10–35 kg/m³. Thermal resistance (EN 12667) ranges from 1.22 to 1.52 m²·K/W.