Thermal insulation

CHEMA STANDARD

XPS Thermal Insulation Boards

CHEMA STANDARD is extruded polystyrene (XPS) foam insulation designed for building roofs and walls. Its lightweight, closed-cell boards help reduce heat transfer through the building envelope, supporting improved indoor thermal comfort and lower cooling-energy demand.

30–32 kg/m³
Density
250–350 kPa
Compressive strength
50°C
Maximum service temperature
24 hours
Maximum uncovered UV exposure
Available grades

Compare grades

Compare grades
PropertyCHEMA BASICCHEMA STANDARDCHEMA PROCHEMA ADVANCED
Product typeExtruded polystyrene (XPS) thermal insulation boardsExtruded polystyrene (XPS) thermal insulation boardsExtruded polystyrene (XPS) thermal insulation boardsExtruded polystyrene (XPS) thermal insulation boards
ApplicationsBuilding roofs and wallsBuilding roofs and wallsBuilding roofs and wallsBuilding roofs and walls
Density28 ± 2 kg/m³30–32 kg/m³32–36 kg/m³36–40 kg/m³
Maximum service temperature122°F (50°C)122°F (50°C)122°F (50°C)122°F (50°C)
Compressive strengthTest method listed; consult the technical data sheet250–350 kPa300–350 kPa350–450 kPa
Flexural strengthTest method listed; consult the technical data sheet———
Oxygen indexTest method listed; consult the technical data sheet———
Water absorptionTest method listed; consult the technical data sheet0.27%0.3%0.2%
Dimensional stabilityTest method listed; consult the technical data sheet0.5%0.5%0.5%
Thermal conductivityTest method listed; consult the technical data sheet0.033 W/(m·°C)0.033 W/m·K0.033 W/(m·°C)
Thermal resistance (R-value)R-5.0 at 1.00 in (25.4 mm) thicknessR-5.0 (0.88 m²·K/W) at 1.00 in (25.4 mm) thickness0.88 m²·K/W (R-5.0)R-5.0 (0.88 m²·K/W) at 1.00 in (25.4 mm) thickness
Water vapour performanceTest method listed; consult the technical data sheet63 (1.1) g/h·m²63 (1.1) g/h·m² at 1.00 in (25.4 mm) thickness63 (1.1) g/h·m² at 1.00 in (25.4 mm) thickness
Minimum flexural strength—450 kPa500 kPa550 kPa
Minimum oxygen index—24%24%24%
Classification—ASTM C578ASTM C578ASTM C578

Overview

CHEMA STANDARD XPS boards provide thermal insulation for roof and wall applications. Manufactured through a continuous extrusion process, the boards feature a homogeneous closed-cell structure that helps resist water absorption and supports thermal resistance and compressive performance. Their lightweight construction makes them convenient to handle, transport, and install as part of a properly designed insulation system.

R-value indicates resistance to heat flow. A higher R-value means greater thermal resistance at the stated thickness. Correctly specified and installed XPS boards improve the thermal performance of the building envelope and can reduce cooling demand.

The continuous extrusion process forms a homogeneous closed-cell structure that helps resist water absorption and retain thermal resistance and compressive performance under suitable service conditions.

Key benefits

Energy Efficiency

Helps reduce heat transfer through roofs and walls and may lower air-conditioning electricity consumption.

Lightweight Construction

Easy to handle, transport and install.

Thermal Comfort

Helps reduce heat transfer through roofs and walls and supports more stable indoor temperatures.

Closed-Cell Structure

The continuous extrusion process forms a homogeneous closed-cell structure that helps resist water absorption and retain thermal resistance and compressive performance under suitable service conditions.

Standards Classification

Classified according to ASTM C578.

Chemical Emissions

GREENGUARD certification is referenced for chemical-emission performance.

Energy Performance

ENERGY STAR® requirements are referenced in the product information.

Zero Ozone-Depletion Potential

Zero ozone depletion is stated in the product information.

Maximum Service Temperature

122°F (50°C)

Product videos

Thermal insulation using Blue XPS Foam boards · CHEMA PRO

Application of extruded polystyrene (XPS) blue foam boards for high-efficiency thermal insulation of roofs, walls and building envelopes, reducing energy consumption by up to 40%.

Blue XPS insulation boards against a masonry wall
Blue XPS insulation boards against a masonry wall
Blue XPS insulation boards against a masonry wall

Technical specifications

Product type
Extruded polystyrene (XPS) thermal insulation boardsProduct information
Applications
Building roofs and wallsProduct information
Classification
ASTM C578ASTM C578
Technical specifications
PropertyTest standardValue
DensityASTM D162230–32 kg/m³
Compressive strengthASTM D1621250–350 kPa
Minimum flexural strengthASTM C203450 kPa
Minimum oxygen indexASTM D286324%
Water absorptionASTM C2720.27%
Dimensional stabilityASTM D696 (as listed)0.5%
Thermal conductivityASTM C5180.033 W/(m·°C)
Thermal resistance (R-value)ASTM C518R-5.0 (0.88 m²·K/W) at 1.00 in (25.4 mm) thickness
Water vapour performanceASTM E9663 (1.1) g/h·m²
Maximum service temperatureProduct information122°F (50°C)

Energy-saving performance depends on building design, insulation thickness, climate, installation quality and the HVAC system. Savings are not a fixed guarantee for every project.

Applications

Roof Thermal Insulation

Thermal insulation for building roofs.

Wall Thermal Insulation

Thermal insulation for building walls.

Roof Insulation Systems

Use with a compatible waterproofing system and the specified protective finish.

How to apply

  1. 01

    Store Under Cover

    Store boards away from direct sunlight and high temperatures.

  2. 02

    Ventilate Storage Areas

    Maintain good ventilation to avoid heat accumulation and reduce the risk of burning or deformation.

  3. 03

    Choose A Cooler Installation Period

    Where practical, install roof boards early in the morning or before sunset to avoid strong direct sunlight.

  4. 04

    Check Surface Temperature

    If the installation surface is excessively hot, allow it to cool before placing the boards.

  5. 05

    Cover Promptly

    Finish or cover installed boards promptly to limit exposure to strong direct sunlight.

  6. 06

    Follow The Specified Roof System

    After roof waterproofing is completed, protect the surface with CHEMA ADVANCED as part of the specified roof system.

  7. 07

    Provide The Protective Finish

    Cover the boards with the specified protective or light cementitious layer where required by the roof build-up.

  8. 08

    Limit UV Exposure

    Cover boards promptly after installation. Do not leave them uncovered and exposed to ultraviolet radiation for more than 24 hours.

  9. 09

    Handle And Store Safely

    Store boards in a covered, well-ventilated area away from direct sunlight and excessive heat. Avoid heat accumulation, sparks and open flames. Handle carefully, avoid strong oxidizing agents and aromatic solvents, and do not stack boards on their edges.

Request a quotation

Share your quantities and project details. Our team will help you select the right specification.

Thermal insulation

CHEMA STANDARD

Product type
Extruded polystyrene (XPS) thermal insulation boards
Applications
Building roofs and walls
Density
30–32 kg/m³
Compressive strength
250–350 kPa

Preparing your enquiry form…

Need help choosing?

Our technical team can help with product selection and project quantities.

Calculate with Chemasure

Frequently asked questions

What is CHEMA STANDARD?

CHEMA STANDARD is extruded polystyrene (XPS) foam insulation for building roofs and walls.

What is CHEMA STANDARD used for?

Thermal insulation of building roofs and walls as part of a suitable building-envelope system.

What are the main benefits of CHEMA STANDARD?

Its lightweight, closed-cell structure provides thermal insulation, ease of handling and resistance to water absorption.

What does R-value mean?

R-value indicates resistance to heat flow. A higher R-value means greater thermal resistance at the stated thickness. Correctly specified and installed XPS boards improve the thermal performance of the building envelope and can reduce cooling demand.

Can the boards remain exposed to sunlight?

Cover boards promptly after installation. Do not leave them uncovered and exposed to ultraviolet radiation for more than 24 hours.

All questions