Stack of light blue Chema Blue Foam insulation boards from Chema Foam company, arranged diagonally on a white background

Chema XPS

Chema XPS Boards are extruded polystyrene foam insulation panels available in four performance levels — Basic, Standard, Pro, and Advanced — engineered to provide exceptional thermal insulation, energy efficiency, and structural durability. Each type offers specific compressive strength and density values to suit diverse building requirements, from residential applications to heavy-duty industrial roofing.

Category      Polystyrene Foam Materials

Facebook
LinkedIn
WhatsApp

Chema XPS is a high-performance extruded polystyrene insulation boards for roofs and walls, available in four grades — Basic, Standard, Pro, and Advanced — offering lightweight, water-resistant, and thermally efficient performance that saves up to 40 % in energy costs.

Properties

01 Lightweight 01 1024x1024

 Lightweight

02 easy to handle and install 01 1024x1024

 easy to handle and install

03 High compressive 01 1024x1024

 High compressive

04 thermal insulation 01 1024x1024

 thermal insulation

02 Resistance to moisture 01 1024x1024

 Water and vapor resistant

06 Long term dimensional stability 01 1 1024x1024

 Long-term dimensional stability

07 Zero ozone depletion potential 01 1024x1024

 Zero ozone depletion potential

08 GREENGUARD certified for low emissions 01 1024x1024

08 GREENGUARD certified for low emissions-01

09 EnergyStar 01 1024x1024

EnergyStar

010 Saves up to 40 of energy consumption 01 1024x1024

 Saves up to 40 % of energy consumption

011 Suitable for exposed or buried insulation systems 01 1024x1024

 Suitable for exposed or buried insulation systems

Areas of Use

06 resistance to sunlight and UV rays 1024x1024

Thermal insulation for roofs

02 Under slab and floor insulation 01 1024x1024

Under-slab and floor insulation

03 Cold storage facilities and refrigerated rooms 01 1024x1024

 Cold storage facilities and refrigerated rooms

04 Concrete sandwich panels 01 1024x1024

Concrete sandwich panels

05 Waterproofing protection layers 01 1024x1024

 Waterproofing protection layers

06 commercial building insulation 01 1024x1024

Industrial and commercial building insulation

 

Application Instructions
1. Surface Preparation:
• Ensure all dust, dirt, and foreign matter are removed from the surface before application.
• For metal surfaces, CHEMA ULTRA LIGHT should be applied over a recommended anti-corrosive coating scheme.

2. Application:
• The product is ready to use. Stir well to ensure a uniform mixture before use.
• Apply the first layer with a trowel, brush, or special spraying pump.
• Apply a second coat when the first is dry to achieve the recommended thickness.

3. Cleanup:
• Clean hands, tools, and equipment promptly with soap and warm water.

Technical Data

DescriptionValue
ColorWhite
Density0.80±0.05 kg/liter
PH Value8+1

Storage & Shelf Life
• Storage: During storage, keep the product tightly closed at temperatures not exceeding 30∘C.
o If you open a package and do not use all of it, seal the lid tightly with plastic wrap to protect the contents from air drying.
• Shelf Life: 12 months when unopened.

Packaging
Available in a 30 kg packages.

 

 

 

Types

PropertyUnitASTM TestChema BASICChema STANDARDChema PROChema ADVANCED
Densitykg/m³D162228 ± 230–3232–3636–40
Compressive StrengthkPaD1621200–250250–350300–350350–450
Flexural Strength (min.)kPaC203400450500550
Oxygen Index (min.)%D286324242424
Water Absorption% (Vol.)C2720.300.270.300.20
Dimensional Stability%D6960.50.50.50.5
Thermal ConductivityW/m·°CC5180.0300.0330.0330.033
Thermal Resistance (R-value)K·m²/WC518(R-5.0) 0.88(R-5.0) 0.88(R-5.0) 0.88(R-5.0) 0.88
Water Vapor Performance (max.)g/h·m²E9663 (1.1)63 (1.1)63 (1.1)63 (1.1)
Max. Service Temperature°C50505050

Storage & Shelf life
• Store panels in a covered, ventilated area away from direct sunlight and heat sources.
• Avoid stacking on edges or near sparks/flames.
• Panels must be covered within 24 hours after installation to prevent UV exposure.
• Indefinite shelf life under proper storage conditions.

Packaging
• Supplied in various thicknesses and sheet sizes according to project requirements.
• Each type is color-coded and labeled for identification (Basic / Standard / Pro / Advanced).

Application
• To begin with installation timing, it’s best to install panels in the early morning or before sunset. This is because it helps avoid exposing them to strong, direct sunlight.
• Following this same principle of managing heat, if the installation surface (concrete or membrane) is too hot, it must be cooled first by spraying water.
• Finishing: After installing the panels, it is important to proceed immediately with the finishing step in order to protect them from direct sunlight. Therefore, the panels should be covered with a light cement layer, which serves as the final protective finish.
• Finally, and most importantly, do not leave panels uncovered for more than 24 hours, as this will prevent damage from prolonged ultraviolet light exposure.